Sign In | Join Free | My himfr.com
Home > ECG Battery >

12v Rechargeable Battery , 4200mAh Battery For Bionet Cardiotouch 3000 CardioCare 2000

    Buy cheap 12v Rechargeable Battery , 4200mAh Battery For Bionet Cardiotouch 3000 CardioCare 2000 from wholesalers
     
    Buy cheap 12v Rechargeable Battery , 4200mAh Battery For Bionet Cardiotouch 3000 CardioCare 2000 from wholesalers
    • Buy cheap 12v Rechargeable Battery , 4200mAh Battery For Bionet Cardiotouch 3000 CardioCare 2000 from wholesalers
    • Buy cheap 12v Rechargeable Battery , 4200mAh Battery For Bionet Cardiotouch 3000 CardioCare 2000 from wholesalers

    12v Rechargeable Battery , 4200mAh Battery For Bionet Cardiotouch 3000 CardioCare 2000

    Ask Lasest Price
    Brand Name : Lee&J. Power
    Model Number : LH-EKG300MD
    Price : negotiation
    Payment Terms : T/T, Western Union, PayPal
    Supply Ability : 100 pcs available
    Delivery Time : 1-2 workdays
    • Product Details
    • Company Profile

    12v Rechargeable Battery , 4200mAh Battery For Bionet Cardiotouch 3000 CardioCare 2000

    12V 4200mAh NI-MH ECG Battery For Bionet CardioTouch 3000 BIONET CardioCare 2000​ ECG


    Product Information


    BrandLee&J. Power
    ReferenceLH-EKG300MD
    ColorGreen
    TypeNI-MH
    Capacity4200mAh
    Voltage12V
    Weight450g
    Size141 x 50 x 28 mm
    Warranty12 months
    Replace CodeGPHC132MOT
    Suitable ForBionet CardioTouch 3000, Bionet CardioCare 2000, CARDIOGIMA 12M

    Detail Image


    Nominal Value


    NO:Item

    Specifications

    1

    Charging voltage

    14V
    2

    Nominal voltage

    12V
    3

    Battery cell specifications

    NI-MH
    4

    Rated capacity

    ≥3800mAh

    5

    Charging current

    Standard charge:0.5C(500mA)

    Fast charging:1C(1000mA)

    6

    Charging method

    The 0.5C (constant current) charge to 14V, then the constant voltage 14V charging until the charging current is less than or equal to 0.01C

    7

    Charging time

    Standard charge: 7.5h

    Fast charging: 3.8h

    8

    Maximum charging current

    1C
    9

    Maximum discharge current

    2C continuous discharge mode (not recommended for long time working in this state)

    10

    Discharge cut-off voltage

    10.0V
    11

    Working temperature

    Charge: 0℃~45℃

    Discharge: -20℃~60℃

    12

    Discharge

    -20℃~+45℃
    13

    Battery weight

    500g±10g
    14

    Battery case material

    PVC

    Battery performance check and test


    1.Visual inspection

    Are there any poor electric property and appearance defects, such as cracks, scratches, melt is not allowed, deformation, dirty, leakage and so


    2.Standard testing conditions

    Unless otherwise specified, the standard book of all tests were carried out in the following conditions

    Temperature:23℃±5℃

    Humidity:65±20%


    3.Charge and discharge performance

    NO

    Item

    measurement method and condition

    Specifications

    1

    Standard charge

    Standard charge standard charge


    First use the 0.5C constant current charge to 14V, then the constant pressure 14V (precision 14 + 0.05V) charges until the charging current is less than or equal to 0.01C

    no
    2

    Initial capacity

    The capacity means after standard charge, discharge to 0.2C 10.0V cutoff voltage out capacity

    ≥3800mAh
    3

    Cycle life of battery core

    A cycle is a charge discharge cycle (20 DEG C, 0.5C charge and discharge current, the 10.0V cutoff voltage)


    When the discharge capacity decreased to 80% initial capacity, cycle times are defined for completion cycle life of the electric core

    4

    High, low temperature discharge characteristics


    After standard charge, discharge at different temperatures (0.2C discharge cut-off voltage 10.0V), comparing the discharge capacity (if the charge and discharge, in different temperature interval of 3 hours), temperature coefficient for discharge capacity and discharge capacity of the temperature of 20 DEG C% ratio.

    The discharge capacity of -10 DEG C. ≥70%

    The discharge capacity of 55 DEG C. ≥90%


    5Self-discharge

    After standard charge, at 25 - 2 Deg. C under 30 days of storage, and then according to the method of measuring the capacity of the project 2.


    Remaining capacity>90%


    6

    Internal resistance of the battery

    After standard charge, measurement of AC impedance under the ACIKZ

    ≤200 MΩ-300 MΩ
    7

    Battery voltage

    Shipment status

    ≥12V

    4.Mechanical properties

    NO

    Item

    Measurement method and condition

    Specifications

    1

    Vibration test

    The standard charge after cell along the X, Y, Z three direction vibration amplitude of each 90 minutes, 1.6mm, vibration frequency 10HZ~55HZ, changing every minute 1HZ.

    No leakage, the capacity retention rate greater than 90% (static battery after 3 hours)

    2

    Drop test

    The standard charge after the battery from the 1 meter drop to the ground 1 times concrete

    No explosion, fire, liquid leakage


    Environmental adaptability test


    Not to mention more environmental adaptation performance shall be in accordance with the corresponding provisions of GB/T18287-2000


    Performance


    NO

    Item

    Measurement method and condition

    Specifications

    1

    Static current consumption

    Test at the temperature of -10-60 DEG C for testing

    In don't pick up any heavy load or short-circuit current (static) inside the<1ųA

    2

    Internal resistance

    The external positive, negative poles connected to 10 ohm load

    The voltage measured between the core and the outer electrical contact terminals and the external end of the negative terminal of a load ratio of anode current value should be<130mΩ

    Product Description


    This battery has been manufactured with high-quality components. It complies with every particular of the orginal manufacturer's regulations and is guaranteed against all manufacturing defects.
    If the capacity (mAh) of the replacement battery is higher than that of the original battery, this will allow for a longer usage time.


    Contact US


    Big wholesale order is acceptable and the price is negotiable, please contact us for details.
    OEM is also welcome. Please tell us the details of the product you want, then we can design and customize it for you.

    Do not hesitate to contact us anytime before and after your purchase. If you have any questions on your purchase, please let me know via "contact now" or by email. We will solve it for you.
    We are committed to ensuring that you are completely satisfied with every transaction. 100% Satisfaction guaranteed !
    We will reply your mail within 24 hours normally. sometimes have a little delay due to the weekends or holidays.
    (we work from Monday to Friday (8-17:30 GTM+8)
    If you can't get our mail after 48 hours, please check your spam or contact to us. If you email us and I will be on service of you until you are satisfied with your purchase.

    Quality 12v Rechargeable Battery , 4200mAh Battery For Bionet Cardiotouch 3000 CardioCare 2000 for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shenzhen Lee&Jack Power Technology Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)